From the eVolve Electrical ribbon, in the Utilities panel, click the Place Hangers button
From an active Project View, Select a section of the run that the hangers will be placed on
Click Finish to bring up the User Place Conduit Hangers window.
Choose a Placement Mode
Entire Path- Entire Run of selected segment(s)
Change of Direction- Ends Auto Hanger placement at the next elbow
Single Hanger- The long way to place one hanger
Setup the Hanger Configuration & Attachment
Hanger Type- We recommend leaving the Auto Detect Type box checked here. This allows the system to decide when to place a single or multi-tiered hanger.
Hanger Spacing- Distance between hangers
Distance From Bend- How far from a bend to place a hanger
Attach to Linked Model
Attach to Reference Plane
Attatch to Nearest Structure Overhead
Distance Below Level
Setup the Strut Configuration
Determine Conduit Position- Where the conduit is placed on the selected strut type
Strut Size- 7/8", 1-5/8", 2-7/16', 3-1/4"
Strut Type- Single Chanel Up, Single Channel Down, Back to Back Channel
Width Rounding- Option to round the width of the rack. 0", 2", 6", 1'
Setup Rod Configuration
Gap Distance- Rod to Conduit Spacing
Center Rod- Optional center support rod. Choose from None, All Hangers, or Set Minimum Width of hangers to add center rods to.
Hanger Attachment- None, Beam Clamp, Blue Banger, Embed, Rod Coupling