Generator w/Optional Pad
In the family browser equipment category, a parametric generator family with an optional pad is available. The family also contains two parametric bottom entry windows that can be positioned wherever needed or turned off. Points are available on the pad, generator, and entry windows.
Identity Data
- Show_ID_3D_Text- Turn on or off the text entered in Equipment_Id visibility
- Show_Part_No_3D_Text- Turn on or off the Equipment_Part_Number visibility
- Show_Tracking_Symbol- Turn on or off for tracking symbol
- Equipment_Part_Number- Enter a part number to be displayed with Show_Part_No_3D_Text
Generator Dimensions
- Equipment_Depth- Generator depth
- Equipment_Width- Generator width
- Equipment_Height- Generator Height
Entry Window Options
- Show_Side_1_Entry- Turn the visibility of side 1 entry on or off
- Side_1_Entry_Length- Length of entry window
- Side_1_Entry_Width- Width of entry window
- Side_1_Entry_Side_Offset- Entry window offset from front face
- Side_1_Entry_Rear_Offset- Entry window offset from left face
- Show_Side_1_3D_Text- Show label text for window
- Side_1_Entry_Label- Enter text to be displayed on the window.
- Show_Side_2_Entry- Turn the visibility of side 2 entry on or off
- Side_2_Entry_Length- Length of entry window
- Side_2_Entry_Width- Width of entry window
- Side_2_Entry_Side_Offset- Entry window offset from back face
- Side_2_Entry_Rear_Offset- Entry window offset from left face
- Show_Side_2_3D_Text- Show label text for window
- Side_12_Entry_Label- Enter text to be displayed on the window.
Pad Options
- Show_Concrete_Pad- Controls visibility of the concrete pad
- Pad_Width_Offset- How far past the edges of the generator will the pad extend in length and width
- Pad_Thickness- Thickness of the pad
Layout Points
- Show_Points_on_Pad- Show the layout points listed
- Show_Points_on_Generator- Show the layout points listed
- Show_Side1_Entry_Points- Show the layout points listed
- Show_Side2_Entry_Points- Show the layout points listed