Enabling/disabling the top clearance of equipment

For coordination, clearances need to be visible. However, clearances may be bothersome if visible in production drawings or plan views. eVolve Electrical can disable the top clearances in certain views while maintaining the visibility of the clearances in the model. This allows for greater control over the visibility, capture proper clearances, and setup templates without having to worry about disabling the visibility in various ways.

  1. While in the desired view, from the ribbon, click the View tab then click Visibility/Graphics from the Graphics panel or type VG from the view.
  2. From the Visibility/Graphic Overrides for… window, on the Model Categories tab, expand Electrical Equipment in the Visibility column.
  3. Check/uncheck the eE Clearance Top checkbox.

Relevant Articles

Manually adjusting the top clearance of equipment

Adjusting the top clearance for equipment from a section view

Adjusting top clearance for equipment in a 3D view

Features for the Equipment Category


How did we do?


Powered by HelpDocs (opens in a new tab)